endstream endobj 176 0 obj <> endobj 177 0 obj <>/ProcSet[/PDF/Text/ImageB]/XObject<>>>/Rotate 0/Type/Page>> endobj 178 0 obj <>stream It can occur when water use exceeds normal delivery capacity of the water supply (e.g., a nearby fire fighting or a water main or service pipe break). A RPBA must always be installed 12 above finished grade or the 100-year flood-plain, whichever is greater and meet all applicable drainage requirements stated herein. 11. 10. The touchpad must be accessible from the right-of-way. than in its supply, i.e. endstream endobj startxref Backflow occurs due to a sudden change in pressure or a break in the water main. 503-823-4000 Traduccin e Interpretacin |Bin Dch v Thng Dch | | |Turjumaad iyo Fasiraad| | Traducere i interpretariat |Chiaku me Awewen Kapas | . If the available area between a building and the property line is adequate (determined by the Bureau), the vault, chamber, or enclosure for the type of backflow assembly required must be installed outside the confines of the building or structure. The platform will need to provide for 6-feet of vertical headroom. For parallel installations, the TEE shall be placed no more than the service pipe diameter, in inches, from the centerline (or outlet side) of the elbow installed on the riser. Assemblies must be installed on private property at the property line (service connection/point-of-delivery as defined in OAR), on the centerline of the city water service as it runs perpendicular from the R.O.W. Highline Water District (HWD) makes no representation The relief-valve must be located 12" above the top of the vault drain opening. Backflow is the reversal in the direction of the normal flow of water in a piping system. Technical assistance in the area of cross-connection control is offered to public water systems by staff from our central office. 103 St. Philip Street PO Box B (29402) Charleston, SC 29403 Directions. Enter your requirements and local pros will bid on your service, providing a quote to complete your request. Give website feedback. Separation must be at least twice the diameter of the water supply outlet and never less than one inch. A reduced pressure type backflow assembly will be required on services to premises with piping systems adjacent to waterways that may be subject to immersion due to periods of highwater incidents. 2023. Approved Areas per TCEQ (click link for more details): Operating or maintaining a Public Drinking Water System, Installing or repairing residential, commercial, or industrial drinking water treatment equipment, Installing or repairing lawn irrigation systems, Performing activities requiring a Master or Journeyman Plumbing license, Testing and repairing backflow prevention assemblies on fire suppression systems and lines. To protect public health, our Cross-Connection Control (CCC) and Backflow Prevention Program is committed to helping you protect your drinking water system from potential contamination. The riser/supply pipe location must meet location criteria as stated herein. @rvk`1i)S8::Al0T h``XS~W23TV9lU4v Some public water systems have licensed staff who perform the CSIs and then bill the customer for the inspection. How can backflow be prevented? 3907 South Industrial Drive If the first upstream manhole is at a higher elevation due to the natural opography of the t area, an alternate method may be selected by the Utility's Development Services Department for the purpose of determining the feasibility of gravity connection. Premises-Isolation Reduced Pressure Backflow Assembly (RPBA) installations requirements. Yes! is booked, canceled, or The water riser/supply pipe must be installed 12 from the foundation frontage wall to centerline of pipe on the centerline of the city water service as it runs perpendicular from the R.O.W. 1002 Washington Ave., 4th Floor These will allow for necessary clearance for ladders in single assembly installations. Effective against backpressure backflow and back-siphonage and may be used to isolate . Please include Cross-Connection/Backflow Prevention in the subject line of your e-mail. RPBA installations must meet all applicable Oregon Administrative Rules, 333-061-0070, Title 21, and Title 28, respectively. Specify the type of backflow prevention device on pool fill line (6-inch or greater air gap, check valve on water to cutoff valve, or siphon breaking valve downstream to cutoff valve). May be mounted on the vault door. An inspection fee must be paid to the Water Bureau prior to replacement of an existing assembly or newly installed assembly on a dedicated fire service. In case the water main had been contaminated, the utility workers had to flush the citys distribution line, too. Water and pesticides flowed from the pesticide tank back through the hose and into the water lines of the residence. When a Double Check Valve Assembly (DCVA) or a Double Check Detector Assembly (DCDA) is installed in a vault the following must be provided: 1. A premises-isolation reduced pressure type backflow assembly is required to be installed on all water service connections as listed but not limited to: premises having private wells, water features (swimming pools), geothermal heating & cooling systems, hydronic heating systems, cooling towers, that have access to rivers, lakes, ponds and/or other water sources that can be connected to; are equipped with storage tanks, rainwater-harvesting (excluding those that simply capture rainwater in containers of less than 50 gallons and gravity-feed to landscape), storm-water or groundwater recovery and reuse systems and/or that use, or reuse treated wastewater (grey and/or black-water) on site. Backflow Assembly Testers in our area. A RPBA is required to be installed on all service connections to vending/food cart lots and lots having below grade drain back yard-hydrants. City of Houston: Lake Houston Dam Spillway Improvement Project: $7,500,000: Texas: . 4. 3. . Sump pump discharge piping must meet vault drainage requirements as stated herein. Normally, water travels in one direction, from treatment plants, through water mains, then to each customers service connection. %%EOF The relief-valve must be located 12 above the top of the vault drain opening. 23828 30th Ave. S. No pressure testing is to be performed between a premises-isolation assembly and a Water Bureau valve in the right-of-way. All above-ground enclosures must be provided with concrete floors/pads, which may not be less than 4 inches in thickness. Fax - 941-365-4840 . Opportunities posted to governmentjobs.com, Legal and installation requirements for backflow protection, City of Portland general information hotline, Backflow prevention and cross-connection control, Oregon Health Authority (OHA) Cross-Connection Control Requirements, Backflow assembly installation requirements, Submitting backflow assembly test reports, Portland Water Bureau manuals and design standards, install a backflow prevention assembly if there's an existing or potential cross-connection on your premises, immediately have your assembly cleaned, repaired or replaced if not working properly. A premises-isolation RPBA must be installed on all water service connections that pose a risk to health. Adequate drainage: Backflow assemblies must not be installed in locations subject to flooding. . Upon completion of a premises-isolation backflow assembly installation, Portland Water Bureau Water Quality Inspection must be notified. Reminders are automatically prevent backflow. the system pressure has been increased by Backflow is the unintended flow of water from any domestic, industrial or institutional piping system into a drinking water supply system. All assemblies 2 and smaller (Excludes fire service assemblies, see information under fire sprinkler services) must be installed no more than 24 below finished grade. SwiftQuote integrates with your municipality and uploads compliance records to the city on your behalf. Information for public water systems and their customers on identifying potential cross connections and preventing contamination from backflow into drinking-water systems. When a DCDA is installed in a vault the metered by-pass must be plumbed on the side of the assembly opposite of the ladder. Depending on how long the backflow event lasts, the contamination could spread to the public drinking water system. This occurs when a supply is interrupted For horizontal installations, and for assemblies which are not approved for vertical up installation, the riser must be equipped with a single 90-degree elbow and the assembly is to be no more than the pipe diameter in inches beyond the centerline (or outlet side of the) elbow to accommodate horizontal installations, excepting only the addition of a wye-strainer, flood control shut off valve or other, necessary appurtenance. Click Here for a copy of the COH Backflow Preventer Test Report and Maintenance Form. You can choose anindividual service providers or select all the providers in their area. 1. If suspended from ceilings, pipe hangers designed to carry the full load of the assembly must be installed. Have a High School Diploma or Equivalent Certificate, Pass an examination *Written exam must be taken at a TCEQ regional office or proctored computer-based testing facility as of May 2, 2016, Work at least two years in an approved area. This usually occurs in unvented heating systems, where The ladder must be mounted vertically in the entryway of the vault or chamber and be securely anchored at top and bottom. The addition of a PWS logo, with no further alterations, to the TCEQ official forms, TCEQ 20699 and TCEQ 20700, does not require submittal or approval of an alternate form. This can be caused by backsiphonage or backpressure. Password (8+ characters) You may also apply directly on company website . 6. Cross-Connection Control Program. Efrain Torres, Environmental Investigator IV. In the An alternate assembly location may only be considered for retrofit applications and excludes new construction. Tablet PCs only support the desktop client. In addition, A voluntary group that is open to anyone who would like to join, the CCC Subcommittee provides us with expanded knowledge and resources to address cross-connection control and backflow prevention throughout Texas. HVK%')dVe%X[oLWR=I Dtrtq3,Vg(&_[N?YG5P[IYH^h\z=d+k,IU%TgrtM%gNYc8-@OiGW.ili\B,|g6 ,~=z. 0 4. 0 Request these services online or call 503-823-4000, Relay Service:711. Ladder orientation must not impede clear access to the assembly and/or vault floor. A moisture-proof light fixture will be required if adequate lighting is not available. A Texas State Board of Plumbing Examiners (TSBPE) licensed Plumbing Inspector. 1. Individuals wishing to obtain a BPAT License, Individuals wishing to obtain continuing education credit, Individuals wishing to obtain a Plumbing Inspectors License, Individuals wishing to obtain information regarding backflow. Assemblies installed directly on vertical subgrade risers, or off a riser which enters the space at less than one foot and necessitates the addition of a vertical run of pipe to be raised to observe the required 12 minimum elevation, must be approved for vertical installation. Retrofit/Replacement backflow assembly installations must meet current State and City installation requirements. On this page: How Cross-Connection and Backflow Can Lead to Contaminated Water Definitions Only 5/8x 3/4 Neptune T-10 positive displacement meters with high resolution registers are to be used. %PDF-1.6 % Payable to: City of Pharr. 12. 797 0 obj <>stream contamination of potable water supplies with foul water. 5. Vacuum Breaker/backflow preventer HPWCODE1100 About Apply Inspections Contact Plan Review Not Required Inspection Required Renewal Not Required Fee $31.95 for first three; $10.65 each additional. How Cross-Connection and Backflow Can Lead to Contaminated Water, TCEQ's regulations for irrigation systems, database of licensed Customer Service Inspectors, Cross-Connection Control (CCC) Subcommittee, Table Listing Common Cross-Connection Hazards, Recommended Practice for Backflow Prevention and Cross-Connection Control, Foundation for Cross-Connection Control and Hydraulic Research, Guide to Cross Connection Protection Devices and Assemblies: Application and Selection, Rules and Regulations for Public Water Systems. This could be caused by pumps, boilers or storage tanks. Permit and plans must be on site for inspection. thermal expansion increases the pressure. To protect public health, our Cross-Connection Control (CCC) and Backflow Prevention Program is committed to helping you protect your drinking water system from potential contamination. See OAR 333-061-0070, Section 14, which specifically addresses existing installations. endstream endobj startxref or drained down. Maintenance requirements include regular testing based on the type of device being used. Potential contamination can make extra protection necessary for landscape irrigation systems, spas, swimming pools, solar water heating systems, or even a bucket of soapy water being filled by a garden hose. Providers are invited to offer quotes for work and can message you directly to understand the job specifics. Vaults must accommodate 6-feet of vertical headroom or have hinged double door opening frame and covers that accommodate the entire lay length of the assembly. maintained by the backflow-prevention education program of the University of Floridas TREEO Center, not all cases of cross connection and backflow end so smoothly. Installations must meet Occupational Safety and Health Administration and State of Oregon Occupational Safety and Health codes. Backflow Prevention Assembly Tester Registration Instructions List of Backflow Prevention Assembly Testers Water Protection Hazard List Approved Backflow Prevention Assemblies List Test and Maintenance Requirements Contact Info 512-972-1060 ext. The riser/supply pipe must be installed 12 from the property frontage foundation wall to the centerline of pipe on the centerline of the city water service as it runs perpendicular from the R.O.W. Provide fence and gate details (drawings) for all types of . REDUCED PRESSURE PRINCIPLE ASSEMBLY. forcing it into a clogged gutter, downspout, or sewer pipe to flush out the clog, connecting it directly to a hose-end sprayer to apply pesticide or fertilizer to your yard, connecting it to a soap-and-brush attachment to wash your car, boat, or siding, letting the end of the hose lie in a puddle or pool of water on the ground. ABPA Certification:If interested in ABPA certification, please contact us for more information. Backflow is a term in plumbing for an unwanted flow of water in General Info (843) 727-7148. assembly tested on an annual basis. The installation of a backflow assembly may alter system operating pressure, flow and/or influence other hydraulic functions. Where existing fire sprinkler system water piping is significantly remodeled (significance determined by the Bureau) or modified, unapproved assemblies and or devices are to be replaced with those currently approved. Only commercially manufactured prefabricated insulated outdoor enclosures are approved. The Association of Contracting Plumbers of the City of New York, Inc. 535 8 th Ave, 17 th Floor New York, NY 10018 (212) 481-4580 All vaults and enclosures for backflow assemblies must be kept free of any debris and/or objects that interfere with these installation requirements and those applicable to OAR 333-061-0071. A RPBA must be installed on domestic water services to mixed-use and multi-tenant premises. A public water systems Cross-Connection Control Program is inspected during routine investigations made by our regional staff. state. To become a City of Pharr registered tester, the following items must be submitted to our office: 1) A copy of your Backflow License (issued by TCEQ) 2) A copy of your Gauge Test Report / Calibration Test Kit. . If it is determined by the Water Quality Inspector that arbitrary runs of exposed piping have been installed prior to an assembly, the assembly may either be required to be relocated or the piping be sleeved. BACKFLOW PREVENTION ASSEMBLY TEST REPORT. 15. Call 503-615-6733 Email Us Visit or send mail to: 150 East Main Street, Third Floor, Hillsboro, Oregon 97123 Frequently Asked Questions Expand/Contract Questions and Answers Highline Water District water service customers who are advised to use their own judgment A TCEQ-licensed Customer Service Inspector. (Minimum Permit Fee is $91.05). $31.95 for first three; $10.65 each additional. 6. Fire systems that incorporate the use of storage tanks must be equipped with a RPDA and are required to be installed at the service connection/point-of-delivery to the premises as outlined herein. Official Cross-Connection Control Program forms: Listed below are links to the official TCEQ Cross-Connection Control Program forms. 16. They identify locations where the risk of cross connection is high and ensure that the proper measures are taken to minimize that risk. Additionally, all piping for fire sprinkler system backflow assembly installations must be compliant with the local Fire code. with respect to contracting with these or any testers. A TSBPE-licensed plumber with a Water Supply Protection Specialist endorsement. Registers must read in cubic feet. What is backflow? ABPA certification also requires an additional fee. accept any responsibilities for the actions or performance of such The relief-valve must be located 12 above finished slab elevation. This reversal of flow direction is known as backflow. Where anti-freeze compounds, chemicals, gases, or any other additives are added to a fire sprinkler system, a Reduced Pressure Detector Assembly (RPDA) will be required. Items can be submitted to our office . Customer water can be exposed to chemicals, microbes and other harmful substances through sinks, irrigation systems, toilets, showers, washing machines, hose bibs, or through commercial fixtures including boilers and cooling towers. The top and bottom rungs must be within 12 of the opening and floor, respectively. 12. Drawings must show property lines, building setbacks, identify street frontage, water main, service location and proposed backflow assembly type and location. Backflow prevention assembly requirements are determined by plumbing inspections performed at initial or remodel construction projects during the Building Permit Process. 2. When a RPBA is installed in a vault or enclosure in a berm or hillside, a horizontal boresight drain to daylight must be provided. Installing an approved backflow prevention assembly and testing it regularly helps protect the water supply from the dangers of cross contamination. Hire a licensed irrigator. You can then select your preferred provider and schedule the service. All exposed piping inside enclosures must be insulated with commercially manufactured closed-cell pipe insulation or a heat source must be provided. The City of Hamilton began a 'Backflow Prevention Program' to protect your drinking water quality by making sure that the appropriate backflow prevention devices had been installed and inspected on private properties in the Hamilton area. State rules and City Codes require you to: Backflow Assembly Installation Requirements. Houston, TX 77002. CE hours are given for successful completion of TCEQ approved training courses. An approved rigidly mounted ladder, with an extension which extends 3 above the vault lid (Oldcastle Infrastructure Pull-Up Extension, Bilco LU-1 or equivalent) is required if the vault or chamber is 4 or greater in depth. A Double Check Detector Assembly (DCDA) is typically the type of backflow assembly installed on fire sprinkler water services. Email my test form to: backflow.utilities@sarasotafl.gov . . . The assemblies are to be installed no more than the pipe diameter in inches from the outlet side of the elbows off the Tee. By continuing to use this website, you consent to the use of cookies in accordance with our Cookie Policy. Planning, outreach and education, strategic, and technology projects. endstream endobj 752 0 obj <. Of the 24 hours, 8 hours must be practical skills (hands-on) training. Water Protection Specialist 1505 Sundog Ranch Rd (928) 777-1615 Email Backflow Prevention devices help to protect the City water system from pollution and contamination by providing a layer of protection at connection points to private water lines. We also coordinate meetings of the Cross-Connection Control (CCC) Subcommittee, a group of participants that meet to discuss issues related to cross-connection control and backflow prevention. The drain must discharge to finished grade and/or be above the 100-year flood plain, whichever is greater. K/7tLb"bxOEuY# O>X}xww-[wZ|=m~8Y{&TXcSv>:.8gXq.ih/}^Mz]z>,NwUUC1->`}>TM;]~a^mvoOzm0P9CLN=MMdD,F?oil1jB).1xU]0SM^D7iLbas,=?W_OFZTum LAq0 d$jpwzcZ hdl%P+]/PGjS)EKafdm50jL:9~I^X#R. A backflow prevention assembly tester that is .